Amerikanische Gesellschaft für Hirudotherapie

Effect of valve design and anticoagulation strategy on 30-day clinical outcomes in transcatheter aortic valve replacement: Results from the BRAVO 3 randomized trial

Randomized controlled trial published in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2017)

Zuletzt aktualisiert: June 18, 2026Geprüft von: ASH Editorial Board
Research article — evidence reviewArticle reference
Evidence: Randomized controlled trialKlinische StudienArzneimittelentwicklungSpeichel-PharmakologieLinke A et al. · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2017

Abstract

BACKGROUND: Selection of valve type and procedural anticoagulant may impact bleeding and vascular complications in transfemoral transcatheter aortic valve replacement (TAVR). We sought to compare outcomes by valve [balloon expandable (BE) or non-BE] and anticoagulant [bivalirudin vs. unfractionated heparin (UFH)] type from the BRAVO-3 trial. METHODS: BRAVO-3 was a randomized multicenter trial including 500 BE-TAVR and 282 non-BE TAVR patients, randomized to bivalirudin versus UFH. Selection of valve type was at the discretion of the operator but randomization was stratified according to valve type. Total follow up was to 30 days. We examined the incidence of Bleeding Academic Research Consortium type ≥3b bleeding, major vascular complications and all ischemic outcomes at 30-days. Outcomes were adjusted using logistic regression analysis. RESULTS: Of the trial cohort, 63.9% were treated with BE valves (n = 251 bivalirudin vs. n = 249 UFH) and 36.1% with non-BE valves (n = 140 bivalirudin vs. n = 142 UFH). Patients treated with non-BE valves were older, with higher euroSCORE I. At 30 days, there were nonsignificant differences between the two valve types for adjusted risk of all-cause death (HR 2.07, 95% CI 0.91-4.70, P = 0.084) and major vascular complications (HR 1.78, 95% CI 0.97-3.26, P = 0.062) with non-BE compared with BE valves, but all other outcomes were similar. A significant interaction was observed between valve and anticoagulant type, with lower risk of major vascular complications with bivalirudin compared with UFH in non-BE TAVR (P-interaction = 0.039). CONCLUSIONS: Majority of patients in the BRAVO 3 trial received BE valves. At 30-days, adjusted risk of clinical outcomes was similar with non-BE vs. BE valves. A significant interaction was observed between valve type and procedural anticoagulant for lower risk of major vascular complications with bivalirudin versus UFH in non-BE TAVR.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal ArticleMulticenter StudyRandomized Controlled Trial
Indexed MeSH termsAged, 80 and overAntithrombinsAortic ValveAortic Valve StenosisCause of DeathDose-Response Relationship, DrugEuropeFemaleFibrinolytic AgentsFollow-Up StudiesHeart Valve ProsthesisHeparin

Zusammenfassung

Selection of valve type and procedural anticoagulant may impact bleeding and vascular complications in transfemoral transcatheter aortic valve replacement (TAVR).

Warum dies für die Hirudotherapie relevant ist

This article reports results from the BRAVO-3 randomized multicenter trial (782 patients; publication type: Randomized Controlled Trial) examining whether valve design (balloon-expandable vs. non-balloon-expandable) and procedural anticoagulant (bivalirudin vs. unfractionated heparin) interact to influence 30-day clinical outcomes in transfemoral transcatheter aortic valve replacement. A significant interaction was observed between valve type and procedural anticoagulant for major vascular complications, with lower risk for bivalirudin versus UFH specifically in non-BE TAVR (P-interaction = 0.039), while other outcomes were similar between valve types. The abstract does not mention leeches, hirudin, or hirudotherapy; its relevance to ASH's domain is therefore not established by the source text.

Zitation

Effect of valve design and anticoagulation strategy on 30-day clinical outcomes in transcatheter aortic valve replacement: Results from the BRAVO 3 randomized trial

Linke A et al. · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2017

Verwandter klinischer Kontext

Zur ASH-Bibliothek hinzugefügt: May 27, 2026 · Letzte Aktualisierung der Website: June 18, 2026

Diese Website stellt Bildungsinformationen bereit und ist weder eine medizinische Beratung noch eine Diagnose oder Behandlungsempfehlung. Die medizinische Blutegeltherapie ist mit klinisch relevanten Risiken verbunden und sollte ausschließlich von qualifizierten Klinikerinnen und Klinikern unter institutionell genehmigten Protokollen durchgeführt werden. Die FDA-510(k)-Zulassung für medizinische Blutegel ist auf bestimmte Indikationen beschränkt; experimentelle und Off-Label-Diskussionen werden entsprechend gekennzeichnet. Für patientenspezifische Beratung wenden Sie sich an eine qualifizierte Gesundheitsfachkraft.