Американское общество гирудотерапии

Avoiding ambient air in test tubes during incubations of human whole-blood minimizes complement background activation

Methodology published in J Immunol Methods (2020)

Последнее обновление: June 18, 2026Рецензент: ASH Editorial Board
Research article — evidence reviewArticle reference
Evidence: Research reportРазработка лекарственных препаратовStorm BS et al. · Journal of immunological methods, 2020

Abstract

BACKGROUND: In vitro, the complement system can be studied in test tubes incubated with anticoagulated human whole-blood. Background activation of complement may mask inflammatory signals. Air bubbles are known to activate complement. We examined if removing ambient air from test tubes before incubation reduced background complement activation. METHODS: Blood from twelve donors was anticoagulated with the thrombin inhibitor lepirudin and incubated with either no air, ambient air or air bubbles in polypropylene tubes at 37 °C for 180 min on a roller mixer. After incubation, EDTA was added, plasma isolated and analyzed for seven complement activation products using ELISA. Results are presented as means with 95% confidence intervals. RESULTS: Blood incubated without air had significantly lower complement activation compared to blood incubated with ambient air; C4d 273 (192-364) vs. 379 (263-494) ng/mL (p = 0.002), C4bc 8.2 (4.1-13) vs. 12 (3.2-21) CAU/mL (p = 0.01), C3a 1351 (873-1838) vs. 2944 (2315-3572) ng/mL (p = 0.0005), C3bc 31 (17-46) vs. 68 (52-84) CAU/mL (p = 0.002), C3bBbP 134 (97-171) vs. 427 (358-506) CAU/mL (p < 0.0001), C5a 3.5 (1.9-5 0.2) vs. 15 (1.8-27)) ng/mL (p = 0.003), TCC 4.6 (2.8-6.3) vs. 9.9 (7.3-12) CAU/mL (p = 0.006). At the end of the experiment blood incubated with air bubbles had a higher complement activation than blood incubated with ambient air with an average 26 fold increase (range 1.6-59) from baseline of all activation products; C4d 551 (337-766) ng/mL, C4bc 21 (5.0-36) CAU/mL, C3a 3983 (3518-4448) ng/mL, C4bc 103 (86-121) CAU/mL, C3bBbP 626 (543-708) CAU/mL, C5a 10 (2.8-18) ng/mL and TCC 10 (6.0-14) CAU/mL. CONCLUSION: Avoiding air in test tubes during whole-blood experiments reduced background complement activation substantially and represents an important improvement to the lepirudin whole-blood model. This could also apply to other in vitro models.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal ArticleResearch Support, Non-U.S. Gov't
Indexed MeSH termsAdultAirAntithrombinsBlood Specimen CollectionComplement ActivationComplement System ProteinsEdetic AcidEnzyme-Linked Immunosorbent AssayFemaleHirudinsHumansMale

Резюме

Lepirudin whole-blood model improved by removing ambient air reduces background complement activation substantially (~26x), critical methodological advance for in vitro inflammation studies.

Почему это важно для гирудотерапии

This study investigated whether removing ambient air from test tubes during incubation of human whole blood anticoagulated with lepirudin reduces background complement activation. Using blood from twelve donors, the authors showed significantly lower activation of seven complement products (C4d, C4bc, C3a, C3bc, C3bBbP, C5a, TCC) when air was excluded, and described this as an improvement to the lepirudin whole-blood model. The abstract refers to lepirudin only as a thrombin inhibitor used for anticoagulation and provides no information on leech biology, leech-derived substances, or hirudotherapy. No leeches, leech secretome components, or hirudotherapy interventions were studied; the work optimizes an in-vitro complement activation assay technique.

Цитирование

Avoiding ambient air in test tubes during incubations of human whole-blood minimizes complement background activation.

Storm BS et al. · Journal of immunological methods, 2020

Связанный клинический контекст

Узнайте, как это исследование связано с клинической практикой

Добавлено в библиотеку ASH: May 27, 2026 · Последнее обновление сайта: June 18, 2026

Этот сайт предоставляет образовательную информацию и не является медицинской консультацией, диагнозом или рекомендацией по лечению. Гирудотерапия сопряжена с клинически значимыми рисками и должна проводиться только квалифицированными клиницистами в рамках институционально утверждённых протоколов. Разрешение FDA 510(k) для медицинских пиявок ограничено определёнными показаниями; обсуждения исследовательского и нелицензионного применения отмечены соответствующим образом. Для индивидуальных медицинских рекомендаций обратитесь к квалифицированному медицинскому специалисту.