Sociedad Americana de Hirudoterapia

Selective inhibition of factor Xa during thrombolytic therapy markedly improves coronary artery patency in a canine model of coronary thrombosis

Animal model study published in Blood Coagulation and Fibrinolysis (1996)

Última actualización: June 18, 2026Revisado por: ASH Editorial Board
Research article — evidence reviewArticle reference
Evidence: Observational studyDesarrollo de fármacosEnsayos clínicosNicolini FA et al. · Blood Coagulation and Fibrinolysis, 1996

Abstract

The success of current thrombolytic strategies is undermined by ongoing thrombin activity, but it is uncertain whether prevention of thrombin generation or direct thrombin antagonism is effective in achieving more optimal thrombolysis. To address this question, 24 dogs with electrically induced coronary thrombus undergoing thrombolysis with tissue-type plasminogen activator (1 mg/kg) over 20 min, were given one of the following adjunctive regimens in a random fashion. Twelve dogs received saline, and served as the control group; a direct thrombin antagonist, hirudin, was given at a dose of 20 micrograms/kg/min for 90 min to six dogs, and a selective factor Xa inhibitor, tick anticoagulant peptide (TAP), was administered to six dogs at a dose of 30 micrograms/kg/min for 90 min. The time to reperfusion was similar in the saline and hirudin groups (34 +/- 4 vs 37 +/- 7 min; P = NS) but shorter in the TAP group (21 +/- 4 min; P < 0.05). Coronary blood flow was restored to 100% of its baseline value for 7 +/- 2 min in control dogs, and for 20 +/- 6 min in the hirudin group (P < 0.05). In the TAP group, coronary blood flow was restored to 100% of its baseline value for more than 120 min in all dogs (P < 0.01 vs others treatments). Reocclusion occurred in 89% and 50% of dogs receiving saline and hirudin, respectively (P = NS), but in none of the TAP-treated dogs (P < 0.01). Plasma fibrinopeptide A (FpA) and thrombin-antithrombin III complex (TAT) levels were determined in all dogs as indicators of thrombin activation. In the saline group, FpA and TAT during reperfusion were 19 +/- 2 ng/ml and 104 +/- 24 ng/ml respectively (P < 0.02 vs baseline) indicating high thrombin activity. In contrast, during reperfusion in hirudin-treated dogs FpA and TAT remained similar to baseline (10 +/- 3 ng/ml and 53 +/- 4 ng/ml respectively; both P < 0.05 vs saline). Reperfusion in TAP-treated dogs did not alter FpA and TAT in plasma, which remained similar to baseline (9 +/- 1 ng/ml and 39 +/- 5 ng/ml respectively; both P < 0.05 vs saline). Scanning electron microscopy of coronary arteries showed residual thrombi with intense platelet and fibrin deposition adherent to the deendothelialized surface of the vessels following saline and hirudin therapy. In contrast, TAP-treated arteries were characterized by the absence of fibrin and minimal platelet deposition. In conclusion, these hemodynamic, biochemical and morphologic data suggest that adjunctive treatment with a higher tier blockade of the coagulation cascade is superior to direct thrombin inhibition in maintaining coronary artery patency following thrombolysis in the experimental canine electrolytic model. These findings highlight the potential adverse effects of unchecked thrombin generation in the setting of thrombolytic therapy.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeComparative StudyJournal ArticleResearch Support, Non-U.S. Gov't
Indexed MeSH termsAnimalsAntithrombinsArthropod ProteinsBlood Coagulation TestsCoronary ThrombosisDisease Models, AnimalDogsFactor Xa InhibitorsFemaleHirudin TherapyIntercellular Signaling Peptides and ProteinsMale

Resumen

Canine coronary thrombolysis model: tick anticoagulant peptide (TAP, factor Xa inhibitor) gave 100% baseline flow >120 min in all dogs vs hirudin (20 min) and saline (7 min); reocclusion 89% saline, 50% hirudin, 0% TAP. Suggests factor Xa blockade superior to thrombin-only inhibition.

Por qué esto importa para la hirudoterapia

This study compared adjunctive saline (n=12), hirudin (n=6), and tick anticoagulant peptide (TAP, n=6) during t-PA thrombolysis in 24 dogs with electrically induced coronary thrombus. Hirudin restored coronary blood flow to baseline for 20 min versus 7 min in controls (P<0.05) and suppressed thrombin activity markers (FpA, TAT), but was markedly inferior to TAP, which maintained patency >120 min with zero reocclusion (P<0.01 vs other treatments). The abstract concludes that adjunctive factor Xa blockade is superior to direct thrombin inhibition in maintaining coronary patency following thrombolysis in this model. Relevance to ASH's domain is indirect: the study evaluates recombinant hirudin but does not mention leeches or hirudotherapy. Limitations include the canine model and small per-arm sample sizes.

Citación

Selective inhibition of factor Xa during thrombolytic therapy markedly improves coronary artery patency in a canine model of coronary thrombosis.

Nicolini FA et al. · Blood Coagulation and Fibrinolysis, 1996

Contexto clínico relacionado

Añadido a la biblioteca ASH: May 27, 2026 · Última actualización del sitio: June 18, 2026

Este sitio web proporciona información educativa y no constituye consejo médico, diagnóstico ni recomendaciones de tratamiento. La terapia con sanguijuelas medicinales conlleva riesgos clínicamente significativos y debe ser realizada únicamente por profesionales calificados bajo protocolos aprobados institucionalmente. La autorización 510(k) de la FDA para sanguijuelas medicinales se limita a indicaciones específicas; las discusiones sobre uso investigativo y fuera de indicación se señalan correspondientemente. Para orientación médica específica, consulte a un profesional de salud calificado.