Sociedad Americana de Hirudoterapia

Bivalirudin for left ventricular assist device thrombosis

Research article published in Journal of thrombosis and thrombolysis (2018)

Última actualización: June 18, 2026Revisado por: ASH Editorial Board
Research article — evidence reviewArticle reference
Evidence: Observational studyDesarrollo de fármacosWeeks P et al. · Journal of thrombosis and thrombolysis, 2018

Abstract

Pump thrombosis remains a serious complication of implantable ventricular assist device therapy and is associated with increased risk of morbidity and mortality. Optimal management strategies remain controversial and are guided largely by limited literature and expert opinion. Medical management of pump thrombosis, including the use of direct thrombin inhibitors, has been associated with mixed results. The purpose of this study is to report the outcomes associated with bivalirudin therapy in LVAD patients with suspected pump thrombosis. A single-center, retrospective observational study of 15 patients with suspected pump thrombosis that were all treated with bivalirudin therapy was conducted. The majority of subjects' initial treatment courses were unsuccessful [9/15 (60%)]; however, 6/15 (40%) achieved an initial improvement in serum lactate dehydrogenase (LDH) levels and were stabilized to be successfully discharged from the hospital. Of the subjects discharged, there was a high rate of recurrence of pump thrombosis within 6 months [5/6 (83.3%)]. Bivalirudin therapy was not associated with a consistent reduction in LDH among all subjects studied, and clinical responses to therapy appear to be associated with high rates of thrombosis recurrence. This study analyzes the largest cohort to date of LVAD patients with pump thrombosis treated with bivalirudin therapy, and suggests that alternative therapies should be considered in management.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal ArticleObservational Study
Indexed MeSH termsAdultAgedHeart VentriclesHeart-Assist DevicesHirudinsHumansL-Lactate DehydrogenaseMiddle AgedPeptide FragmentsRecombinant ProteinsRecurrenceRetrospective Studies

Resumen

Pump thrombosis remains a serious complication of implantable ventricular assist device therapy and is associated with increased risk of morbidity and mortality.

Por qué esto importa para la hirudoterapia

This observational study examined the outcomes of using bivalirudin therapy to treat suspected pump thrombosis in 15 patients with left ventricular assist devices (LVADs). The researchers found that bivalirudin therapy was initially unsuccessful for the majority of patients and was associated with high rates of thrombosis recurrence among those who were stabilized and discharged. The authors suggest that alternative therapies should be considered for managing LVAD pump thrombosis. The abstract makes no mention of hirudin, leech saliva, or hirudotherapy, meaning any connection to the American Society of Hirudotherapy's domain is entirely unsupported by this specific source.

Citación

Bivalirudin for left ventricular assist device thrombosis

Weeks P et al. · Journal of thrombosis and thrombolysis, 2018

Contexto clínico relacionado

Añadido a la biblioteca ASH: May 27, 2026 · Última actualización del sitio: June 18, 2026

Este sitio web proporciona información educativa y no constituye consejo médico, diagnóstico ni recomendaciones de tratamiento. La terapia con sanguijuelas medicinales conlleva riesgos clínicamente significativos y debe ser realizada únicamente por profesionales calificados bajo protocolos aprobados institucionalmente. La autorización 510(k) de la FDA para sanguijuelas medicinales se limita a indicaciones específicas; las discusiones sobre uso investigativo y fuera de indicación se señalan correspondientemente. Para orientación médica específica, consulte a un profesional de salud calificado.