Validation of Tabletop Microscopes for Microsurgery Simulation and Training

Validation study published in J Oral Maxillofac Surg (2022)

Última actualización: 18 de junio de 2026Revisado por: ASH Editorial Board
Artículo de investigación — revisión de evidenciaReferencia del artículo
Evidence: Research reportEnsayos clínicosBest DL et al. · Journal of oral and maxillofacial surgery, 2022

Abstract

PURPOSE: Oral and maxillofacial surgery residency programs are increasingly adopting microsurgery as a core element of training; however, many barriers exist that limit trainees' proficiency. The purpose of this study was to perform a validation of 2 tabletop microscope simulations for their use as a training tool, which could serve as an affordable, alternative method to traditional microsurgery training methods. METHODS: A prospective, single-institution, multidepartmental validation study was performed. Two microscopes (monocular digital [DM] and binocular stereo [SM]) were used to perform anastomoses on simulation vessels including a silastic tube and a chicken thigh femoral artery. A microsurgeon panel was selected from a population of microsurgery faculty and fellows at Michigan Medicine (Ann Arbor, MI) to perform the anastomoses. The surgeons each performed 4 anastomoses, using each microscope with each vessel, and subsequently completed a survey evaluating the simulation. Predictor variables were the microscope and the vessel. Primary outcome variable was readiness for use, which was defined as the simulation's ability to incorporate into a microsurgical training curriculum in its current state. Secondary outcome variables included realism, value, usefulness, relevance, difficulty, and cost. Paired t tests were used to compare responses. Alpha was set to 0.05. RESULTS: Seven microsurgeons performed the simulation from the departments of oral and maxillofacial surgery (n = 5), plastic and reconstructive surgery (n = 1), and otolaryngology (n = 1). For readiness, the SM simulation required either no modification (n = 4) prior to implementation into a microsurgery curriculum or minimal modification (n = 3), compared to the DM simulation which required significant modification (n = 4) or extensive modification and re-evaluation (n = 3) (P = .002). The SM demonstrated a greater mean realism score than the DM for depth perception (5.00 vs 1.57, P < .001), field of view (4.57 vs 3.57, P = .038), lighting (5.00 vs 4.00, P = .038), and clarity (5.00 vs 3.86, P = .030). There was no statistically significant difference between SM and DM in value, usefulness, relevance, difficulty, or cost. CONCLUSIONS: Tabletop microscopes demonstrate considerable promise in the future of microsurgical education. The SM simulation was a realistic simulation that may be ready for use in a microsurgical curriculum. Future studies are required to demonstrate the efficacy of this simulation on microsurgical trainees.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal Article
Indexed MeSH termsClinical CompetenceInternship and ResidencyMicrosurgeryProspective StudiesSimulation TrainingSurgery, Plastic

Resumen

Validation study of monocular versus binocular stereo tabletop microscopes for microsurgery simulation; stereo microscope (SM) outperformed digital monocular (DM) in depth perception, field of view and clarity.

Por qué esto importa para la hirudoterapia

Este estudio prospectivo de validación examinó dos simulaciones de microscopio de sobremesa (monocular digital y estereoscópico binocular) para su uso en el entrenamiento en microcirugía, evaluando la preparación, el realismo y otros factores de evaluación mediante una encuesta a un panel de siete microcirujanos tras realizar anastomosis en vasos de simulación. La simulación estereoscópica binocular obtuvo puntuaciones significativamente más altas en la preparación para la implementación curricular y en las métricas de realismo, incluyendo percepción de profundidad, campo de visión, iluminación y claridad. Este artículo no tiene relevancia directa para la hirudoterapia, el secretoma de la sanguijuela ni para el ámbito de la Sociedad Americana de Hirudoterapia —evalúa la óptica del entrenamiento quirúrgico y dispositivos de simulación, y no contiene ninguna mención a sanguijuelas, compuestos derivados de sanguijuelas ni técnicas de hirudoterapia.

Citación

Validation of Tabletop Microscopes for Microsurgery Simulation and Training.

Best DL et al. · Journal of oral and maxillofacial surgery, 2022

Contexto clínico relacionado

Explore cómo esta investigación se conecta con la práctica clínica

Añadido a la biblioteca ASH: May 27, 2026 · Última actualización del sitio: 18 de junio de 2026

Este sitio web proporciona información educativa y no constituye consejo médico, diagnóstico ni recomendaciones de tratamiento. La terapia con sanguijuelas medicinales conlleva riesgos clínicamente significativos y debe ser realizada únicamente por profesionales calificados bajo protocolos aprobados institucionalmente. La autorización 510(k) de la FDA para sanguijuelas medicinales se limita a indicaciones específicas; las discusiones sobre uso investigativo y fuera de indicación se señalan correspondientemente. Para orientación médica específica, consulte a un profesional de salud calificado.