Sociedad Americana de Hirudoterapia

Near infrared spectroscopy in monitoring of head and neck microvascular free flaps

Research article published in Bratislavske lekarske listy (2023)

Última actualización: 18 de junio de 2026Revisado por: ASH Editorial Board
Artículo de investigación — revisión de evidenciaReferencia del artículo
Evidence: Research reportDesarrollo de fármacosCzako L et al. · Bratislavske lekarske listy, 2023

Abstract

OBJECTIVES: Microvascular free‑flap monitoring is crucial to the early detection of flap failure and increases the chance of early intervention in case of disruption of perfusion to a flap. Many clinical alternatives to classical clinical flap monitoring have been proposed, such as color duplex ultrasonography, handheld Doppler, flap thermometry, or implantable Doppler flowmetry. Early detection of critical changes in tissue oxygenation can lead to successful surgical intervention when problems with flap nutrition arise. METHODS: Our clinical study seeks to investigate dynamic monitoring of free flaps with near‑infrared spectroscopy (NIRS). NIRS is a non-invasive instrumental technique used for continuous monitoring of peripheral tissue oxygenation (StO2) and microcirculation. All patients were included prospectively from one clinical center. RESULTS: During the clinical research period, 18 patients underwent extraoral head and neck reconstruction with one of three types of free flap, namely with radial forearm free flap (RFFF), anterolateral thigh flap (ALT) or fibula free flap (FFF). Measurements of flap perfusion were taken using NIRS during intraoperative and postoperative phases for 71 hours on average. A total of 6 perfusion disorders were recorded, of which three originated from microanastomoses and three from postoperative bleeding and compression of pedicle. NIRS showed characteristic changes in all 6 cases that were returned to the operating theatre owing to pedicle compromise. In these cases, NIRS had detected the pedicle compromise before it was clinically identified. A single StO2 monitoring was able to detect the vascular compromise with 100% sensitivity and 95.65% specificity. None of the cases were falsely positive. In our study, all compromised flaps were accurately identified by means of NIRS. In most cases, the changes in oxygen saturation became evident on NIRS prior to being clinically observed. CONCLUSION: In our study, the continuous NIRS monitoring securely detected the early stages of arterial and venous thromboses or pedicle compression. The most important aspects of monitoring the flaps´ microvascular perfusion and vitality by means of NIRS lie in its function of recording the dynamics of changes in the values ​​of absolute oxygen saturation (StO2> 50%) alongside with detecting a 30% decrease in tissue saturation over a 60‑minute interval (60 min StO2 >30%) before the clinical changes in the microvascular flap become observable. In cases of pedicle compression, the average time of appearance of signs of StO2 values dropping below the reference interval (as detected by NIRS) was 1:29:02 hour (SD= 0:58:42 h) prior to the occurrence of any clinical signs, while in cases of microvascular anastomosis complications, it was 0:35:23 hour (SD=0:08:30 h)  (SD = 0:08:30 h) (Tab. 3, Fig. 7, Ref. 42).

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal Article
Indexed MeSH termsHumansFree Tissue FlapsSpectroscopy, Near-InfraredPlastic Surgery ProceduresPostoperative Complications

Resumen

Microvascular freeflap monitoring is crucial to the early detection of flap failure and increases the chance of early intervention in case of disruption of perfusion to a flap.

Por qué esto importa para la hirudoterapia

Este estudio clínico prospectivo evaluó la monitorización mediante NIRS de la saturación tisular de oxígeno (StO2) en 18 pacientes sometidos a reconstrucción de cabeza y cuello con colgajos libres de antebrazo radial, muslo anterolateral o peroné, registrando 6 trastornos de perfusión durante un periodo medio de monitorización de 71 horas. El NIRS detectó todos los casos de compromiso del pedículo con una sensibilidad del 100% y una especificidad del 95,65%, identificando los cambios aproximadamente 1,5 horas antes de los signos clínicos en los casos de compresión y 35 minutos antes en los casos de microanastomosis. Para el ámbito de ASH, la relevancia es indirecta: la detección precoz del compromiso vascular del colgajo libre podría propiciar intervenciones, incluida la terapia con sanguijuelas para la congestión venosa, pero el resumen no menciona sanguijuelas ni hirudoterapia. La salvedad es que este estudio se centra en la tecnología de monitorización óptica para la vigilancia de colgajos, sin participación de sanguijuelas.

Citación

Near infrared spectroscopy in monitoring of head and neck microvascular free flaps

Czako L et al. · Bratislavske lekarske listy, 2023

Contexto clínico relacionado

Explore cómo esta investigación se conecta con la práctica clínica

Añadido a la biblioteca ASH: May 27, 2026 · Última actualización del sitio: 18 de junio de 2026

Este sitio web proporciona información educativa y no constituye consejo médico, diagnóstico ni recomendaciones de tratamiento. La terapia con sanguijuelas medicinales conlleva riesgos clínicamente significativos y debe ser realizada únicamente por profesionales calificados bajo protocolos aprobados institucionalmente. La autorización 510(k) de la FDA para sanguijuelas medicinales se limita a indicaciones específicas; las discusiones sobre uso investigativo y fuera de indicación se señalan correspondientemente. Para orientación médica específica, consulte a un profesional de salud calificado.