An optimized method to assess in vivo efficacy of antithrombotic drugs using optical coherence tomography and a modified Doppler flow system
Research article published in Journal of pharmacological and toxicological methods (2011)
Abstract
INTRODUCTION: Animal models of venous and arterial thrombosis are extremely useful to study the efficacy of antithrombotic agents. Variability in efficacy data is often observed in those preclinical studies. The goal of this study was to optimize the methodology for assessing antithrombotic drug efficacy by the use of optical coherence tomography (OCT) and a modified Doppler flow system in rat models of thrombosis. METHODS: Thrombus formation was assessed in both the rat venous and arterial ferric chloride (FeCl(3)) models of thrombosis. In the venous model, thrombus volume post-treatment was measured using OCT, and data were correlated against the thrombus weight. In the arterial model, the time to occlusion was measured using a Doppler flow probe connected to a perivascular flow module which allowed the reporting of dynamic blood flow data every 30s. Heparin (130 or 165U/kg), argatroban (4.5mg/kg), bivalirudin (1.3mg/kg) or saline were administered intravenously. RESULTS: In the venous model, for all treatment groups a strong linear correlation (R(2)=0.998) was observed between thrombus volume measured by OCT and thrombus weight. In the arterial model, using a high sampling rate of a dynamic blood flow using a modified Doppler flow system provided data accuracy and precision of the time to occlusion measurement. DISCUSSION: This study demonstrates that OCT is a powerful tool for the assessment of antithrombotic drug efficacy. Furthermore, it shows that a high Doppler sampling rates of dynamic blood flow leads to data accuracy and precision.
Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.
Summary
This methods study validated optical coherence tomography thrombus-volume measurement (linear correlation with thrombus weight, R2 = 0.998) and a high-sampling Doppler flow system in rat FeCl3 thrombosis models using heparin, argatroban, and bivalirudin.
Why This Matters for Hirudotherapy
This methodological study optimized assessment of antithrombotic drug efficacy using optical coherence tomography (OCT) and a modified Doppler flow system in rat FeCl₃-induced venous and arterial thrombosis models. Heparin, argatroban, bivalirudin, or saline were administered intravenously as test treatments; a strong linear correlation (R²=0.998) between OCT-measured thrombus volume and thrombus weight was demonstrated in the venous model, and the modified Doppler system provided accurate and precise time-to-occlusion measurement in the arterial model. The study's purpose is imaging methodology validation for preclinical antithrombotic assessment. Bivalirudin (formerly Hirulog) is a synthetic peptide anticoagulant designed partly on the C-terminal sequence of hirudin, the anticoagulant of the medicinal leech (Maraganore et al., 1990); this paper studies the drug, not leech therapy.
Citation
Reference (Vancouver style)
Couture L, Richer LP, Cadieux C, Thomson CM, Hossain SM. An optimized method to assess in vivo efficacy of antithrombotic drugs using optical coherence tomography and a modified Doppler flow system. J Pharmacol Toxicol Methods. 2011;64(3):264-268. doi:10.1016/j.vascn.2011.09.001. PMID: 21967828
Bibliographic details (authors, volume, pages, DOI) are taken from the PubMed record.
Added to ASH library: May 27, 2026 · Site last updated: June 18, 2026