American Society of Hirudotherapy

Specific factor Xa inhibition reduces restenosis after balloon angioplasty of atherosclerotic femoral arteries in rabbits

Animal model study published in Circulation (1994)

Last Updated: June 18, 2026Reviewed by: ASH Editorial Board
Research article — evidence reviewArticle reference
Evidence: Preclinical (animal)Drug DevelopmentGenomics & ProteomicsRagosta M et al. · Circulation, 1994

Abstract

BACKGROUND: Balloon angioplasty of atherosclerotic arteries results in activation of the coagulation cascade. Several coagulation factors, including factor Xa and thrombin, are mitogenic for vascular smooth muscle cells in vitro and thus may play a role in restenosis after balloon angioplasty. Specific inhibition of factor Xa can be achieved with recombinant antistasin (rATS) or tick anticoagulant peptide (rTAP). We hypothesized that inhibition of Xa would limit restenosis after balloon angioplasty in an atherosclerotic rabbit model. METHODS AND RESULTS: Focal femoral atherosclerosis was induced by air desiccation injury and a high-cholesterol diet in 38 New Zealand White rabbits. Recombinant antistasin (n = 20 arteries) or rTAP (n = 14 arteries) was administered by intravenous bolus at the time of balloon angioplasty and followed by a 2-hour infusion; controls (n = 21 arteries) received bolus heparin alone (150 U/kg). Therapeutic prolongation of the activated partial thromboplastin time occurred, and antithrombotic drug levels were achieved in all animals. Luminal diameter in millimeters by quantitative angiography did not differ between treatment groups before (1.1 +/- 0.2 for controls, 1.1 +/- 0.2 for rATS, and 1.1 +/- 0.3 for rTAP) or after balloon angioplasty (1.5 +/- 0.3 for controls, 1.4 +/- 0.2 for rATS, and 1.4 +/- 0.2 for rTAP). At 28 days, treatment with factor Xa inhibitors tended to result in arteries with larger luminal diameter than controls (1.2 +/- 0.3 for rATS, 1.2 +/- 0.3 for rTAP versus 1.0 +/- 0.3 for control, P = .09 by one-way ANOVA). Restenosis, defined as reduction in angiographic luminal diameter (in mm) from 2 hours after angioplasty to 28 days after angioplasty was less in the rATS group than in controls (-0.2 +/- 0.1 versus -0.5 +/- 0.4, P < .001) and tended to be less in the rTAP group (-0.3 +/- 0.2 versus -0.5 +/- 0.4, P = .07). Quantitative histopathological analysis showed less percent cross-sectional area narrowing by plaque in both rATS- and rTAP-treated arteries compared with controls (42 +/- 21%, 47 +/- 18%, and 63 +/- 14%, respectively; P < .01 by one-way ANOVA). CONCLUSIONS: We conclude that a 2-hour infusion of rATS or rTAP reduced angiographic restenosis and resulted in less luminal cross-sectional narrowing by plaque compared with controls.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal ArticleResearch Support, Non-U.S. Gov't
Indexed MeSH termsAngioplasty, BalloonAnimalsArteriosclerosisArthropod ProteinsFactor Xa InhibitorsFemoral ArteryIntercellular Signaling Peptides and ProteinsInvertebrate HormonesLeechesMalePeptidesRabbitsRadiographyRecurrenceTicksTime Factors

Summary

In an atherosclerotic rabbit model of femoral balloon angioplasty, a 2-hour infusion of recombinant antistasin or recombinant tick anticoagulant peptide, selective factor Xa inhibitors, reduced angiographic restenosis and cross-sectional plaque narrowing at 28 days versus heparin-treated controls.

Context

This study evaluated whether specific factor Xa inhibition with recombinant antistasin (rATS) or recombinant tick anticoagulant peptide (rTAP) could reduce restenosis after balloon angioplasty in an atherosclerotic rabbit model. Focal femoral atherosclerosis was induced in 38 New Zealand White rabbits, with treatment allocated per artery (rATS n=20 arteries, rTAP n=14 arteries, heparin control n=21 arteries). At 28 days, rATS-treated arteries showed significantly less angiographic restenosis (−0.2 ± 0.1 mm vs −0.5 ± 0.4 mm for controls, P<0.001), and both rATS and rTAP groups showed less cross-sectional plaque narrowing (42% and 47% vs 63% control, P<0.01). The abstract does not mention leeches or hirudotherapy. Limitations include the animal model and some rTAP comparisons reaching only trend-level significance (P=0.07).

Citation

Reference (Vancouver style)

Ragosta M, Gimple LW, Gertz SD, Dunwiddie CT, Vlasuk GP, Haber HL, et al. Specific factor Xa inhibition reduces restenosis after balloon angioplasty of atherosclerotic femoral arteries in rabbits. Circulation. 1994;89(3):1262-1271. doi:10.1161/01.cir.89.3.1262. PMID: 8124815

Bibliographic details (authors, volume, pages, DOI) are taken from the PubMed record.

Added to ASH library: May 27, 2026 · Site last updated: June 18, 2026

This website provides educational information and does not constitute medical advice, diagnosis, or treatment recommendations. Medicinal leech therapy carries clinically meaningful risks and should be performed only by qualified clinicians under institutionally approved protocols. FDA 510(k) clearance for medicinal leeches is limited to specific indications; investigational and off-label discussions are labeled accordingly. For patient-specific guidance, consult a qualified healthcare provider.