Monitoring Breast Reconstruction Flaps Using Near-Infrared Spectroscopy Tissue Oximetry
Research article published in Plastic surgical nursing : official journal of the American Society of Plastic and Reconstructive Surgical Nurses (2024)
Abstract
Free flap reconstruction is a common procedure with success rates greater than 99%. However, vascular complications may occur, resulting in flap failure. For this reason, early detection of vascular compromise is crucial for flap salvage. Vascular complications may be detected early by monitoring tissue oximetry parameter changes using near-infrared spectroscopy (NIRS). This method of noninvasive monitoring can evaluate changes in flap oxygenation levels caused by arterial and venous thrombosis before surgical reexploration. The goal of this study was to assess the validity of using NIRS oximetry for monitoring free flaps. We conducted a prospective cohort observational study of 10 patients undergoing breast reconstruction. We used the INVOS 7100 cerebral oximetry monitoring system (Medtronic, Dublin, Ireland) to provide 24-hr continuous postoperative monitoring of flap perfusion and compared the data with clinical assessment findings. The median patient age was 57 years (range = 41-61 years). Patients underwent immediate breast reconstruction with deep inferior epigastric perforator (DIEP) flap surgery (n = 4), delayed reconstruction with DIEP flap surgery (n = 4), transverse upper gracilis flap surgery (n = 1), and latissimus dorsi flap with lipofilling (n = 1). We successfully monitored all 10 flaps for 24 hr postoperatively. The overall flap survival rate was 100%. Findings of clinical examination, Doppler studies, and surgical outcome were consistent with NIRS monitoring. In conclusion, NIRS tissue oximetry could potentially provide a noninvasive method for effective postoperative monitoring of free flaps.
Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.
Summary
A prospective cohort study of 10 breast reconstruction patients used continuous near-infrared spectroscopy to monitor flaps for 24 hours postoperatively; all flaps survived, and NIRS findings were consistent with clinical examination and Doppler studies.
Context
This prospective cohort observational study of 10 patients evaluated the use of near-infrared spectroscopy (NIRS) tissue oximetry for 24-hour continuous postoperative monitoring of free flaps in breast reconstruction, finding 100% flap survival and consistency between NIRS readings, clinical examination, Doppler studies, and surgical outcomes. The abstract notes that NIRS can evaluate changes in flap oxygenation caused by arterial and venous thrombosis before surgical reexploration. The study does not involve leeches, hirudotherapy, or any leech-derived agents. The study addresses a perfusion monitoring technology in flap surgery without any leech-related content.
Citation
Reference (Vancouver style)
Kumbasar DE, Hagiga A, Dawood O, Berner JE, Blackburn A. Monitoring Breast Reconstruction Flaps Using Near-Infrared Spectroscopy Tissue Oximetry. Plast Surg Nurs. 2021;41(2):108-111. doi:10.1097/PSN.0000000000000380. PMID: 34033637
Bibliographic details (authors, volume, pages, DOI) are taken from the PubMed record.
Added to ASH library: May 27, 2026 · Site last updated: June 18, 2026