American Society of Hirudotherapy

A Bioinspired and Cost-Effective Device for Minimally Invasive Blood Sampling

Engineering / device published in Adv Sci (2024)

Last Updated: June 18, 2026Reviewed by: ASH Editorial Board
Research article — evidence reviewArticle reference
Evidence: Research reportDrug DevelopmentSalivary PharmacologyZoratto N et al. · Advanced science, 2024

Abstract

Conventional venipuncture is invasive and challenging in low and middle-income countries. Conversely, point-of-care devices paired with fingersticks, although less invasive, suffer from high variability and low blood volume collection. Recently approved microsampling devices address some of these issues but remain cost-prohibitive for resource-limited settings. In this work, a cost-effective microsampling device is described for the collection of liquid blood with minimal invasiveness and sufficient volume retrieval for laboratory analyses or immediate point-of-care testing. Inspired by the anatomy of sanguivorous leeches, the single-use device features a storage compartment for blood collection and a microneedle patch hidden within a suction cup. Finite Element Method simulations, corroborated by mechanical analyses, guide the material selection for device fabrication and design optimization. In piglets, the device successfully collects ≈195 µL of blood with minimal invasiveness. Additionally, a tailor-made lid and adapter enable safe fluid transportation and integration with commercially available point-of-care systems for on-site analyses, respectively. Taken together, the proposed platform holds significant promise for enhancing healthcare in the pediatric population by improving patient compliance and reducing the risk of needlestick injuries through concealed microneedles. Most importantly, given its cost-effective fabrication, the open-source microsampling device may have a meaningful impact in resource-limited healthcare settings.

Abstract sourced from PubMed (NCBI) for the cited record. See the original publication for the authoritative version.

Publication typeJournal ArticleResearch Support, Non-U.S. Gov't
Indexed MeSH termsAnimalsSwineCost-Benefit AnalysisEquipment DesignBlood Specimen CollectionPoint-of-Care SystemsHumansModels, Animal

Summary

Leech-inspired bioinspired blood-sampling device for point-of-care use in low/middle-income settings, mimicking the leech's painless feeding mechanism for minimally invasive sample acquisition.

Why This Matters for Hirudotherapy

This study describes a single-use, cost-effective microsampling device for minimally invasive blood collection, explicitly inspired by the anatomy of sanguivorous leeches, featuring a concealed microneedle patch within a suction cup and a blood storage compartment. In piglets, the device collected approximately 195 µL of blood with minimal invasiveness, aiming to improve pediatric compliance and reduce needlestick injuries in resource-limited settings. The connection to ASH is purely bioinspirational—no leeches, leech secretome components, or hirudotherapy techniques are involved; the leech serves only as an anatomical design archetype for an engineering device.

Citation

A Bioinspired and Cost-Effective Device for Minimally Invasive Blood Sampling.

Zoratto N et al. · Advanced science, 2024

Added to ASH library: May 27, 2026 · Site last updated: June 18, 2026

This website provides educational information and does not constitute medical advice, diagnosis, or treatment recommendations. Medicinal leech therapy carries clinically meaningful risks and should be performed only by qualified clinicians under institutionally approved protocols. FDA 510(k) clearance for medicinal leeches is limited to specific indications; investigational and off-label discussions are labeled accordingly. For patient-specific guidance, consult a qualified healthcare provider.